Description
The Chromatotec microVOC is a compact PID VOC analyzer that allows continuous and real time qualification and quantification of benzene, toluene, ethylbenzene, xylenes in standards and other VOCs (optional).
Key points:
- Compact & portable.
- Easy to use: set up in less than 5 minutes.
- Color touch screen with standard & expert user modes.
- Fast & accurate measurements.
- Measuring time of 10 minutes.
- High sensitivity.
- Less than 1 ppb detection limit for Benzene.
- Battery or mains operation.
- Low carrier gas consumption.
- Calibration with a gas mixture of BTEX or Toluene gas.
- Compatible with the use of canisters and the FLEC® system
- Sequential programming, analysis follow-up & data recording.
- Data recording for quality control.
From French academic research:
- Innovation of the CNRS and the University of Strasbourg.
- Patented microfluidic device.
- Supported by EU and innovation programs.
Certifications :
- IEC/EN 61010-1:2010
- EMC: NF EN 61326-1:2013
Optional:
- Teflon sampling line (OD: 1/8''; L: 150 cm).
- Other VOCs such as: methanol, phenol, acrolein, 1-3 butadiene, ETO, THT, TBM, naphthalene and others on request.
- 3G module.
- Air Report: online measurement reporting tool.
Features
- Measurement ranges :
0-1000 ppb
0-10 ppm / 0-100 ppm / 0-1000 ppm
- Detection limit :
Benzene and toluene: ~ 1 ppb
Ethylbenzene and m+p-Xylenes: ~ 2 ppb (with default settings) / o-Xylene: ~ 4 ppb
- Response time: one measurement every 10 minutes (default settings).
- Sampling:
200 μl loop or less
Gas flow rate: 10 to 100 mL min-1
Carrier gas: Nitrogen 4 bar inlet pressure and 2.5 mL min-1
Supply inlet connection: 1/8
- Data logging: yes
- Display: 7" TFT screen; 800 x 480 resolution; integrated touch screen
- Software :
On-board software: Expert and standard modes
Data backup on 32 GB microSD card with over 13 months of continuous data storage capacity
Setup, launch and monitoring of the analysis
Failure and maintenance management.
- Communication :
USB: Data transfer (area, retention time, concentration)
Ethernet: Communication and remote control
- Power supply: Input 100 - 240V ±10%; 1.5A max; 47 - 63Hz - Output 15V; 6.67A 100W
- Dimensions & weight:
Analyzer: 32×28×15 cm; 6.0 kg
Case: 56 x 45 x 25 cm; 18 kg
Applications
- Occupational Exposure Verification of Public Buildings
- Industrial hygiene measurements
- Chamber test studies
- Quantification of material emissions
- Building management
- Continuous monitoring of concentration levels
- Field campaign