You are here : Home1 / Gas detectors : Leaks2 / Teledyne GT Series...

Teledyne GT Series
Leak detector CH4 / LEL / CO / H2S /O2

Request a quote
This product is already in the request for quote list.
Browse the list
Categories : Gas Detectors: Leakage, Gas Detectors: Portable, Gas Detectors: Air Quality, Sales: Portable Tags : Catalytic sensor, CH4, CO, Thermal conductivity (TCD), Gas detector, Electrochemical (ECD), H2S, LEL / LIE, Multigas, O2, Pressure, Semiconductor
  • Description
  • Features
  • Documentation

Description

The GT series is a leak detector suitable for the following operations: Leak testing, confined space entry, borehole testing, carbon monoxide, purging, sniffer and pressure sealing.

Applications: Leak testing, confined space entry, borehole testing, carbon monoxide, purging, sniffer and pressure sealing

Types of gases: Carbon monoxide (CO), flammable gas (LEL), methane (CH4), hydrogen sulphide (H2S), oxygen (O2)

Available modes:

  • Gas leakage: measures methane in 3 different scales (ppm, LEL and Vol). Automatic switching between scales.
  • Confined spaces: simultaneous measurement of 4 gases (O2, LEL, H2S and CO) with appropriate alarms and recording of values.
  • Carbon Monoxide: measures CO leaks in 3 approaches: direct, differential or compensated (if an O2 cell is integrated).
  • Barhole: Multi-sampling .
  • Purge: measures methane in the 0-100 vol% range in inert atmospheres.
  • Sniffer: measures methane micro-leaks thanks to the semi-conductor cell located at the end of the probe. The audible and luminous alarms make it possible to determine precisely the zones of leak.
  • Pressure: In this mode, the instrument can be used as a pressure gauge to measure the pressure of the unit (via its sensor on the back of the unit) and check for leaks (0 to 150 mBar (resolution 1 mBar).

Benefits:
- PPM, LEL/LEL and flammable gas ranges in Vol% Methane for leak detection
- Manual and automatic data logging
- Powerful and highly visible audible counter (Geiger) in the ppm range
- Built-in flashlight
- Alkaline or rechargeable battery option
- Charging via simple power cable or docking station
- Rugged polycarbonate housing with IP54 protection

Features

Gas Measuring range Resolution Type of sensor
O2 0 – 25 % 0.1% Electrochemical
CO 0 - 2000 ppm 1 ppm Electrochemical
H2S 0 - 100 ppm 1 ppm Electrochemical
Toxic sensor
double (CO/H2S)
0 - 2000 ppm/
0 - 100 ppm
1 ppm Electrochemical
CH4 0 - 10,000 ppm 1 ppm Semiconductor
CH4 0 - 100 % LEL 1 % Sensor
catalytic
CH4 0 - 100 % Volume 1 % Conductivity
conductivity
Gauge/
water indicator
- 60 inches /
0 - 1.52 meters H2O
or
0 to 150 mbar
0.1 inch /
0.25 cm
1mbar
Differential pressure
differential pressure sensor

 

Documentation

Brochure
EN brochure

Similar products

  • HY-ALERTA 500
    H2 DETECTOR

    Read more View details
  • ION GASCHECK G
    Leak detector
    Helium, Hydrogen, Argon, Nitrogen and others

    Read more View details
  • MultiRAE Lite
    Portable multi-gas detector
    Up to 6 gases

    Read more View details
  • VPAC II
    Gas leak detector

    Read more View details

360 avenue de la Rasclave
Z.I. Braye de Cau
13821 La Penne-sur-Huveaune
France

+33(0)4 91 87 82 10
cleanair.europe@cleanair.com

OUR EQUIPMENT

  • New measuring instruments
  • Gas Analysers
  • Mercury analyzers & samplers
  • Gas Detectors
  • Particle Counters & Analyzers
  • Dust Samplers
  • Gas Sampling Systems
  • Isokinetic Sampling Systems

    ABOUT

  • Blog
  • Career
  • Contact

OUR SERVICES

  •   Rental
  • Sale
  • Maintenance
  • Calibration
logo CB visa mastercard
Copyright - CleanAir Europe - Enfold Theme by Kriesi
  • LinkedIn
  • Facebook
  • General Conditions of Direct Sales
  • Privacy Policy
Inficon Hapsite ER
GC...
ToxiRAE Pro PID
PID...
Scroll up
We use cookies to improve our content and services, but also to provide you with a safer experience. You can accept all cookies or manage your preferences via the "Personalise" menu. Learn more about our use of cookies and data.
CustomizeACCEPT
Manage consent

Setting cookies

Cookies classified as necessary are stored on your browser because they are essential for the basic functionality of our website. We also use third-party cookies that allow us to analyse the performance of our website. You have the option to disable these cookies. Please note, however, that disabling some of these cookies may affect your experience of browsing the site and the online services we can offer you.
Necessary cookies
These cookies are necessary for the proper functioning of our website and its services. These cookies do not store any personally identifiable information.
Performance cookies
These cookies allow us to understand and analyze key analytical performance indicators, which helps to provide a better user experience.
Advertising cookies
These cookies are used to provide visitors with relevant advertising and marketing campaigns. These cookies track visitors to the websites and collect information to provide personalized advertisements.
Save & Apply