CleanAir Europe
  • Home
  • Our Services
      •   Rental
      • Maintenance
      • Calibration
  • Instruments
      • New measuring instruments
      • Gas Analysers
      • Mercury Analysers / Samplers
      • Gas Detectors
      • Particle Counters / Analysers
      • Dust Samplers
      • Gas Sampling Systems
      • Isokinetic Sampling Systems
      • Multiparameter Equipments
      • Thermal Cameras
      • Refurbished Equipments
  • Blog
  • Contact
  • About
      • About CleanAir
      • Career
  • My Quote
  • Connection
  • Search
  • Menu Menu
  • 0Basket
You are here: Home Home1 / Mercury Analysers - Samplers2 / CleanAir MET-80...
Image of a CleanAir MET-80 Mercury monitoring system

CleanAir MET-80
Mercury monitoring system

Request a quote
This product is already in the request for quote list.
Browse the list
Category: Mercury analysers - Samplers Tags : Gas analyser, Hg, Absorbent trap, Isokinetic dust sampler
  • Description
  • Configurations
  • Features
  • Documentation
  • Animation

Description

CleanAir 's MET-80 Sorbent Trap Mercury Monitoring System provides accurate, NIST-traceable and repeatable mercury measurements with the highest degree of confidence and availability available in the industry. The MET-80 is designed for continuous, high-performance monitoring. Manufactured with mechanically simple, industry-tested parts, the system requires only a few hours per week to operate, keeping your operating costs predictable and manageable.

The MET-80 is built on the same powerful platform that includes a dual channel MFM gas sampling, compressor based gas conditioning, National Instruments cRIO based programmable automation controller. The MET-80 also uses CleanAir's preeminent METRIC ™ software.

For applications where space is limited and easy installation is essential, CleanAir also offers the MET-80 CLS. An even lower profile cabinet solution than the MET-80CL, the MET-80 CLS features a small custom fiberglass enclosure (24 "x 48" x 12 ") that includes the same half inch of insulation as the MET-80 CL. It can be mounted on a wall or other accessible structure near the port location. It can also be left on the wheeled stand on the stacking platform to move between units as needed.

Configurations

 

MET-80 CL

MET-80 CLS

MET-NOMAD

MET-X

Monitoring or Sampling Purpose

MATS Compliance  
Portland Cement NESHAP Compliance  
PS-12B  
EPA Method 30B    
LEE Performance Testing      
Hg Speciation Testing
Specialized Sorbent Trap Testing (e.g. HCl)    

Hardware Features

Dual Sorbent Traps
Mass Flow Meter TechnologyIntegration
Custom Insulated Enclosure
Portable System
Dual Scrubber Assembly
Calibration Audit Integration
Compatible Scanner
MET-80 Probe Compatible
Integrated Chiller with MET-NOMAD MC
Sampling Flow Rate Range 50 - 2000 cc/min 50 - 2000 cc/min 50 - 2000 cc/min 50 - 2000 cc/min

Software Features

METRIC Software (Developed by CleanAir)
Easy to Use Software Interface and Control
Alarm History
Integrated Data Download
Comprehensive Alarming
SMART Stack Flow Input Mapping/SFSR Management
Seemless DAHS Integration (Analog / Modbus TCP)
Remote Access & Control

Technical Specifications

Dimensions 24 "x48 "x16" 24 "x48 "x12" 11″x22″x20″ 17″x15″x7″
Approximate 250 200 30 20
Power Requirements (VAC/Qty-Amps) 120 VAC (2-20A/EA) 120 VAC (2-20A/EA) 120 VAC (1@20A) 120VAC (1@15A)
Mounting Wall/Stand Wall/Stand Custom/ Temporary Temporary
Heating and Cooling 900W/2200BTU 900W/2200BTU

Additional Options

Service and Calibration Audit Plan
Maintenance and Special Services Plan
Spare Parts Plan
Specialized Monitoring Design Services

Features

The MET-80 autosampler consists of a dual gas sampling and conditioning system. The system is designed with mechanical redundancy in mind and includes two high precision dual range mass flow controllers and two high capacity diaphragm sampling pumps. Each sample line has its own independent flow control valve and temperature and pressure measurement components. Some of the other design features include:

  • Main MATS Compliance Monitor
  • Start/stop redundancy available via two probes or four probes (single probe with four gas channels)
  • Integration with factory control networks
  • On-line calibration
  • Sorbent bar code reader
  • Quick change sorbent trap probe
  • Fiber optic networking and integration into factory DAHS
  • Semiconductor mass flow meter volume measurements
  • 95% data availability
  • High-speed operation to reduce RATA test times
  • Meter calibration audits performed without downtime
  • NEMA-4 controlled environment shelter option
  • Sampler equipment located anywhere in the plant
  • Remote access to data and sampler functions
  • Automated moisture measurement
  • Fully alarmed to prevent loss of samples or data
  • Online scrubber exchange
  • Integrated valve manifolds

Documentation

Brochure
MET-NOMAD brochure
MET-X Brochure

Animation

https://2yvvsl17v7eq3m8lp21tmeo8-wpengine.netdna-ssl.com/wp-content/uploads/2020/12/met-80-animation_71.mp4

 

Similar products

  • CleanAir Heavy Metals
    Isokinetic Gas System

    Read more View details

360 avenue de la Rasclave
Z.I. Braye de Cau
13821 La Penne-sur-Huveaune
France

+33(0)4 91 87 82 10
cleanair.europe@cleanair.com

CFM and Measurement Network logo

OUR EQUIPMENT

  • New measuring instruments
  • Gas Analysers
  • Mercury analyzers & samplers
  • Gas Detectors
  • Particle Counters & Analyzers
  • Dust Samplers
  • Gas Sampling Systems
  • Isokinetic Sampling Systems

    ABOUT

  • Blog
  • Career
  • Contact

OUR SERVICES

  •   Rental
  • Sale
  • Maintenance
  • Calibration
logo CB visa mastercard
Copyright - CleanAir Europe - Enfold Theme by Kriesi
  • LinkedIn
  • Facebook
  • General Conditions of Direct Sales
  • Privacy Policy
ToxiRAE Pro PID
PID...
Thermo Scientific Model 15i...
Scroll up
We use cookies to improve our content and services, but also to provide you with a safer experience. You can accept all cookies or manage your preferences via the "Personalise" menu. Learn more about our use of cookies and data.
CustomizeACCEPT
Manage consent

Setting cookies

Cookies classified as necessary are stored on your browser because they are essential for the basic functionality of our website. We also use third-party cookies that allow us to analyse the performance of our website. You have the option to disable these cookies. Please note, however, that disabling some of these cookies may affect your experience of browsing the site and the online services we can offer you.
Necessary cookies
These cookies are necessary for the proper functioning of our website and its services. These cookies do not store any personally identifiable information.
Performance cookies
These cookies allow us to understand and analyze key analytical performance indicators, which helps to provide a better user experience.
Advertising cookies
These cookies are used to provide visitors with relevant advertising and marketing campaigns. These cookies track visitors to the websites and collect information to provide personalized advertisements.
Save & Apply