A blue globe icon next to the word "CleanAir" in bold blue letters, forming the CleanAir brand logo on a black background.

Thermo Scientific TVA1000

Portable FID VOC Analyzer

Available for rent
ATEX/IECEx Certified

The Thermo Scientific TVA1000 is a portable gas analyzer available in a single-FID configuration or with a simultaneous dual FID/PID detector. It measures a wide range of volatile organic compounds (VOCs) and hydrocarbons, including methane, over a dynamic range of up to 50,000 ppm or a linear range of up to 10,000 ppm.

VOCs
HCT
Flame Ionization Detection (FID)
Photoionization Detection (PID)

Industrial Processes

INDUSTRIAL PROCESSES
•Combustion Optimization (Furnaces, Boilers)
•Inerting Control and Process Safety
•Process Gas Purity Analysis
•Protection of Catalysts and Equipment
•Manufacturing Process Control

Fugitive Emissions

FUGITIVE EMISSIONS
•LDAR (Leak Detection and Repair) Programs
•Fenceline monitoring
•Measurement of VOCs in Ambient Air
•Sanitation facility
•Monitoring of Landfills and Waste Facilities

An optimal detection solution FOR YOUR FUGITIVE EMISSIONS

Particularly well-suited for fugitive emissions, the Thermo Scientific TVA1000 ensures highly precise monitoring with a detection limit as low as 100 ppb for benzene (PID) and 300 ppb for hexane (FID). This portable VOC analyzer offers optimal responsiveness thanks to its internal pump, which ensures a response time of just 3.5 seconds. Its portable and lightweight design simplifies your on-site operations.

To accommodate the complexity of your readings, the interface is available in two probe versions (standard 4-digit or advanced with a 6-line display). The system ensures the reliability of your operations with alarms for high and low thresholds and STEL exposures. Its high-performance internal memory can store between 800 and 18,000 data points, depending on the selected configuration mode.

Its rechargeable NiCd battery provides 8 hours of runtime, covering all of your daily operations. CleanAir Europe offers the TVA1000 and the Thermo Scientific TVA2020 , which is its improved and more recent version.

MEASUREMENT RANGES Dynamic: 0.5 to 2,000 ppm (PID) isobutylene; 0.5 to 50,000 ppm (FID) methane
Linear: 0.5 to 500 ppm (PID) isobutylene; 0.5 to 10,000 ppm (FID) methane
Detection THRESHOLDS 100 ppb benzene (PID)
300 ppb hexane (FID)
CLARIFICATIONS FID: 25% of the measured value or 2.5 ppm, whichever is higher, from 1.0 to 10,000 ppm
PID: 25% of the measured value or 2.5 ppm, whichever is higher, from 0.5 to 500 ppm
T90 RESPONSE TIME 3.5 seconds
FLOW RATE 1,000 cc/min
BATTERY Rechargeable NiCd
RANGE 8 o'clock
ALARMS Low, High, STEL
PROBE Bar graph and 4-digit LCD (standard)
6 lines x 20 characters (advanced version)
storage of measurements From 800 to 18,000 points, depending on the mode
communication Bluetooth available as an option
ANALOG OUTPUTS 0–2 Vdc
Dimensions 343 x 262 x 81 mm
WEIGHT Analyzer: 5.8 kg
Packaged: 17 kg
Dual FID/PID Technology
Combining FID and PID Technologies for the Analysis of VOCs in Ambient Air.
Dynamic & Linear Ranges

Dynamic response up to 50,000 ppm (FID) and guaranteed linear accuracy up to 10,000 ppm.

Improved Responsiveness

Instant test results with a response time of 3.5 seconds.

Internal Memory
Storage capacity of 800 to 18,000 measurement points with Bluetooth communication option.
Autonomy & Safety

NiCd battery providing 8 hours of runtime and built-in safety alarms (High, Low, STEL).

MANUFACTURER'S DOCUMENTATION
EN Technical Data SheetDownload