You are here: Home Home1 / Gas analyzers: Emissions & Process2 / ETG 6900 TDLS HCl...

ETG 6900 TDLS HCl
HCl H2O analyzer

Request a quote
This product is already in the request for quote list.
Browse the list
Categories : Gas analyzers: Emission & Process, Gas analyzers: Air Quality, Location: Ambient Air, Location: Emission & Process, News Tags : Gas Analyser, H2O, HCl, Laser Spectroscopy (TDLS)
  • Description
  • Features
  • Documentation

Description

CleanAir Europe offers the ETG 6900 TDLS HCl analyzer for rental. This analyzer uses an improved TDLS (Tunable Diode Laser Spectrometry) to detect this gas, whose narrow bandwidth laser beam (0.1 nm) scans in the absorption band of the target gas, providing a high-resolution infrared absorption measurement.

The ETG 6900 TDLS HCl analyzer can reliably and selectively measure HCl at low ppm concentrations without the need for frequent calibration. This makes it ideal for monitoring hydrochloric acid emissions from landfill sites, or for applications at remote sites, e.g. in environmental research.

Used primarily inwaste incineration processes, hydrochloric acid (HCl) continuous emission monitoring system(CEMS) applications have been in circulation for several years.

Chlorine in plastics burned in incinerators tends to combine with moisture in the basket to form HCl during the combustion process.

Hydrochloric acid, in addition to other acid gases, has generally always been controlled in post-combustion cleaning systems, such as acid gas scrubbers (wet or dry).

These systems typically control a variety of acid gases as well as the toxicity level of the air.
HCl release levels downstream of abatement devices are generally low in most applications: single digit ppm levels and typically less than 30 ppm.

CleanAir Europe also offers the following analyzers ETG 6900 TDLS NH3 analyzer with the same technology for continuous NH3 measurements.

Available for rent 

CleanAir Europe offers the ETG 6900 TDLS HCl gas analyzer for rent. A complete solution can be integrated including a heated probe with filter, heated line and standard gas.

Features

ETG 6904 H Thermal Analyser for HCl analysis of hot and humid gases:
- Hot water analyser for HCl analysis based on laser technology.
- Hot and humid sample to be analysed
- Suitable for 19" rack mounting
- Minimum standard range 0-50/100 ppm
- Maximum standard range 0-500 ppm
- Detection limit 0.2 ppm
- Output signal 4-20 mA, Modbus, Profinet, Profibus, etc.

Documentation

CleanAir EN Data Sheet
CleanAir EN Data Sheet
EN Data Sheet

Similar products

  • ETG 4500 EIMS
    Multigas Traces Analyzer
    Traces VOC, NH3, HCL, HF, NOx & Cl2

    Read more View details
  • ETG 6900 TDL NH3
    Ammonia Analyzer NH3 H2O

    Read more View details
  • MKS MultiGas 2030
    Multigas FTIR Analyzer

    Read more View details
  • CleanAir Corrosive Gases
    Isokinetic Gas System

    Read more View details

360 avenue de la Rasclave
Z.I. Braye de Cau
13821 La Penne-sur-Huveaune
France

+33(0)4 91 87 82 10
cleanair.europe@cleanair.com

CFM and Measurement Network logo

OUR EQUIPMENT

  • New measuring instruments
  • Gas Analysers
  • Mercury analyzers & samplers
  • Gas Detectors
  • Particle Counters & Analyzers
  • Dust Samplers
  • Gas Sampling Systems
  • Isokinetic Sampling Systems

    ABOUT

  • Blog
  • Career
  • Contact

OUR SERVICES

  •   Rental
  • Sale
  • Maintenance
  • Calibration
logo CB visa mastercard
Copyright - CleanAir Europe - Enfold Theme by Kriesi
  • LinkedIn
  • Facebook
  • General Conditions of Direct Sales
  • Privacy Policy
Honeywell Sensepoint XCL...Honeywell Sensepoint XRL...
Scroll up
We use cookies to improve our content and services, but also to provide you with a safer experience. You can accept all cookies or manage your preferences via the "Personalise" menu. Learn more about our use of cookies and data.
CustomizeACCEPT
Manage consent

Setting cookies

Cookies classified as necessary are stored on your browser because they are essential for the basic functionality of our website. We also use third-party cookies that allow us to analyse the performance of our website. You have the option to disable these cookies. Please note, however, that disabling some of these cookies may affect your experience of browsing the site and the online services we can offer you.
Necessary cookies
These cookies are necessary for the proper functioning of our website and its services. These cookies do not store any personally identifiable information.
Performance cookies
These cookies allow us to understand and analyze key analytical performance indicators, which helps to provide a better user experience.
Advertising cookies
These cookies are used to provide visitors with relevant advertising and marketing campaigns. These cookies track visitors to the websites and collect information to provide personalized advertisements.
Save & Apply