2030 item 198

This analyzer can measure a large number of compounds. Its sensitivity varies between percentage and parts per million ranges depending on the compound and the application.
The MKS 2030 uses the FTIR detection principle.
It is mainly used for measuring atmospheric discharges, adjusting processes, yield of catalytic converters and engine exhausts.
It consists of a patented FTIR 2102 spectrometer with a high resolution optical bench. The software includes various applications and has a library of spectra by compound for quantitative analysis of molecules.
 

Specification

– Measurement Ranges : from 1 ppm to 100 % depending on the gas component.
– Units : ppm, %
– Sensitivity : to the ppm for multiple components.
– Sample flow-rate : 0.2 to 10 l/mn.
– Sample : < 200 °C and < 30%V humidity.
– Outputs : RJ-45 Ethernet, analog
– Voltage: 110 or 240 V 50/60 Hz, 3 amps
– Packaged weight : 50 kg
– Recommended for use with : 813, 830, 846, 622, 926, 923
 

Key Points

– Requires liquid nitrogen to operate.
– Portable computer provided with software pre-installed and configured.

43C item 250

Cet appareil permet de mesurer le SO2.
Le Thermo 43C utilise le principe de la photométrie dans l’ultraviolet. Il possède un dispositif de compensation de température et de pression.
Il peut mesurer le H2S ou TRS après un convertisseur à oxydation thermique.

Caractéristiques

– Gamme de mesure : programmable de 0-1-100ppm
– Seuil de détection : 1 ppb
– Unités : ppb, ppm ou mg/m3 programmable
– Stockage des mesures : 5000 points de mesure
– Pompe interne : oui
– Sortie analogique : 0-10V
– Interface de communication PC : oui
– Logiciel : oui
– Poids emballé : 28 kg
– Nombre de colis : 1
– Conseillé avec articles : 141, 622, 922, 927

Points clés

– Menus de paramétrage et de diagnostics optiques et électroniques
– Commutation automatique d’échelles
– Temps de réponse rapide
– Linéarité sur toutes les échelles
– Susceptibilité réduite aux interférents
– Utiliser du tube PTFE pour limiter les pertes par absorption

42C-HL item 151

The analyzer can measure NO, NOx and NO2 simultaneously.
The Thermo 42C-HL uses the principle of chemiluminescence to measure emissions of NO (by direct measurement) and NOx and NO2 by conversion to NO.
It is used after an NO2 converter gas treatment system with a yield of greater than 97%.

Specification

– Measurement Range : programmable 0 – 10 ppm and 0 – 5000 ppm
– Units : ppm, mg/m3
– Detection Limit : 50 ppb
– Data storage : 5000 measurement points
– Internal pump : none (external pumps supplied).
– Analog Output : 0 – 10V
– Communication interface: yes
– Software : Yes
– Packaged weight: 50 kg
– Number of packages : 2
– Recommended for use with : 622, 820, 831, 846, 921

Key Points

– Menus for setting parameters and for optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Microprocessor controlled
– Excellent sensitivity
– Reduced sensitivity to interference
– Network connection
– 19’’ rack

Gas 3000 item 547

This portable analyzer can measure CH4, CO2, O2 and H2S for biogas applications.

The GAS 3000 uses infra-red detection for CH4 and CO2 and electrochemical cells for O2 and H2S.

It is used to measure gas in the soil, to monitor landfills and waste processing sites and for biogas quality control.

It is supplied with a probe and a hydrophobic filter.

Specification

– Ranges : 0 – 100% CH4, 0 – 50% CO2, 0 – 25% O2, 0 – 5000 ppm H2S
– Units : %, ppm
– Internal Pump : yes
– Data Storage : yes
– Communication interface : yes
– Software : yes
– Recommended for use with : 622

Key Points

– Battery Life : 4 to 6 hours

HF & HCI item 311H

The machine can sample HF and HCl.

It is a variant of the base model (dust). It uses nozzles and a Pyrex duct with a compartment containing 4 impingers.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5m, 15m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5
 

 

Key Points

– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.

AP 360 item 236

This machine measures NOx in the open air to determine air quality or to set a zero baseline before building construction work is carried out.

The Horiba AP360 uses the principle of chemiluminescence.
It can be used after a dilution system on a high concentration application (such as emissions).

 

Specification

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
Communication interface : yes
– Packaged weight : 25 kg
– Number of packages : 1
– Recommended for use with : 622, 921P, 927

330L item 136

This gas analyzer can measure CO and O2. CO2 is calculated depending on the type of fuel.
The Testo 330L uses the principle of an electrochemical cell and is mainly used for small and medium sized boilers.

Specification

– Measurement Range :  0 – 4000 ppm CO and 0 – 20% O2.
– Units : ppm, %
– Data Storage : 200 measurement points
– Detection Limit : 1 ppm CO and 0.1% Vol. O2
– Software : yes
– Packaged weight : 3 kg
– Number of packages : 1

Key Points

– Gas sensor remaining life readout
– Automatic monitoring of level in condensate drain with alert if it is too full
– Error messages with description and diagnostics
– Reminder on date of last maintenance check
– Analyzer internal temperature readout

Jerome J405 item 560

This portable machine will measure mercury vapor in ambient air.

The Jerome J405 uses gold film detection.

It can be used to monitor mercury spillages at hazardous waste sites, dumps, water conduits and so on.
There is very little interference compared to a UV detector.
 

Specification

• Measurement Range : 0.5 – 999 μg/m3
• Unit : μg/m3
• Ambient Air: 0 °C- 45 °C on non-condensable and non-explosive gas.
• Flowrate : 750 cc/min
• Detection Limit : 0.5 μg/m3
• Data Storage: 20000 measurement points
• Internal Pump : yes
• Communication interface : yes
• Software : yes

 

Key Points

• Weight for user : 2.5 kg
• Charger power supply (can operate on a 12V battery, not supplied)
• Automatic zero calibration

Dry Cal-DC Lite item 475

This machine measures the displacement time of a graphite piston in a glass cylinder to calculate volumetric flow in liters per minute. Flow is measured step by step, continuously or continuously with the average. It is used to adjust individual pumps. Specification – Scale from 100 ml/min to 7l/min. – Packaged weight: 2 kg – […]

AP 360 item 241

This machine measures O3 in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses the principle of UV fluorescence.
It can be used after a dilution system on a high concentration application (such as emissions).

Caractéristiques

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 927