CleanAir Europe
  • Home
  • Our Services
      •   Rental
      • Maintenance
      • Calibration
  • Instruments
      • New measuring instruments
      • Gas Analysers
      • Mercury Analysers / Samplers
      • Gas Detectors
      • Particle Counters / Analysers
      • Dust Samplers
      • Gas Sampling Systems
      • Isokinetic Sampling Systems
      • Multiparameter Equipments
      • Thermal Cameras
      • Refurbished Equipments
  • Blog
  • Contact
  • About
      • About CleanAir
      • Career
  • My Quote
  • Login | Logout
  • English
    • Français
    • Deutsch
    • Italiano
  • Search
  • Menu Menu
  • 0Basket
Vous êtes ici : Accueil1 / Systèmes de Prélèvement Isocinetique : Composants Système2 / Pompe à Filtre Chauffée en ligne <...

Heated In-Line Filter Pump
CleanAir Heated In-Line Filter Pump Assembly

Request a quote
This product is already in the request for quote list.
Browse the list
Categories : Isocinetic Sampling Systems : System Components, Gas Sampling Systems: Accessories, Sales: Accessories & Spare Parts, Sales: Gas Sampling Lines
  • Description

Description

Clean Air Engineering 's heated EMC inline filter and pump is intended for emissions testing and chemical analysis. It is important to maintain a constant temperature around 120°C to ensure that moisture, acid gas and other constituents of the gas stream do not condense before entering the analytical equipment. This can lead to equipment damage as well as loss of important data. The heated in-line filter and pump assembly helps ensure the accuracy of gas samples by providing a heated path for the gas prior to analysis. The filter, stainless steel needle valve and pump are insulated and heated. This unit includes a dual heating controller. All components are modular and therefore easy to maintain. The unit is also small and light, making it easy to transport. For use in: process monitoring, stack testing, EMC, gas and diesel sampling.

The heated filter holder in line with a heated ADI sample pump for gas sample delivery. This combination can be used with an extractive FTIR system or other hot CEMS to provide a particle-free hot sample flow for your measurement system.

Specifications of the heated in-line filtration pump:
Weight: 18Kg
Dimensions: 31 x 43 x 54 (L x W x H) cm
Maximum pump flow rate: 27 l / min
Pump amperage: 3.6-4.0 amps
Pump heater amperage: 1.25 amps
Pump power: 120/240 volts, 60/50 Hz
Pump Heater Power: 2 @ 75 watts with type K thermocouple
Pump: 316SS single head with Teflon® diaphragm
Maximum pump heating temperature: 205°C
Filter Heater Power: 338.82 watts
Heater amperage: 2.82 amps
Maximum filter heater temperature: 205°C
Voltage Requirements: 120 VAC
Model Filter Size: 1.5" x 5.5" (2.54 cm x 17.78 cm)
Inlet and outlet fittings: 3/8" stainless steel compression fitting

EN brochure
Manual EN

Similar products

  • Spare parts & consumables
    In Situ Gas Probe

    Read more View details
  • PSG Plus Extruded
    HEATED SAMPLING LINE

    Read more View details
  • Vignette PSG Basic

    PSG Basic
    Gas sampling probe

    Read more View details
  • Nozzles and orifices

    Read more View details

360 avenue de la Rasclave
Z.I. Braye de Cau
13821 La Penne-sur-Huveaune
France

+33(0)4 91 87 82 10
cleanair.europe@cleanair.com

OUR EQUIPMENT

  • New measuring instruments
  • Gas Analysers
  • Mercury analyzers & samplers
  • Gas Detectors
  • Particle Counters & Analyzers
  • Dust Samplers
  • Gas Sampling Systems
  • Isokinetic Sampling Systems

    ABOUT

  • Blog
  • Career
  • Contact

OUR SERVICES

  •   Rental
  • Sale
  • Maintenance
  • Calibration
logo CB visa mastercard
Copyright - CleanAir Europe - Enfold Theme by Kriesi
  • LinkedIn
  • Facebook
  • General Conditions of Direct Sales
  • Privacy Policy
Teflon tube
Tubes...
ADI Dia-Vac sampling pump...
Scroll up
We use cookies to improve our content and services, but also to provide you with a safer experience. You can accept all cookies or manage your preferences via the "Personalise" menu. Learn more about our use of cookies and data.
CustomizeACCEPT
Manage consent

Setting cookies

Cookies classified as necessary are stored on your browser because they are essential for the basic functionality of our website. We also use third-party cookies that allow us to analyse the performance of our website. You have the option to disable these cookies. Please note, however, that disabling some of these cookies may affect your experience of browsing the site and the online services we can offer you.
Necessary cookies
These cookies are necessary for the proper functioning of our website and its services. These cookies do not store any personally identifiable information.
Performance cookies
These cookies allow us to understand and analyze key analytical performance indicators, which helps to provide a better user experience.
Advertising cookies
These cookies are used to provide visitors with relevant advertising and marketing campaigns. These cookies track visitors to the websites and collect information to provide personalized advertisements.
Save & Apply