CleanAir CATECO Dust
Isokinetic Gas System

Request a quote
This product is already in the request for quote list.
Browse the list
Categories : Location: Emission & Process, Isokinetic Sampling Systems Tags: cleanair, Particulate Matter, Dust, Isokinetic dust sampler, isokinetic system
  • Description
  • Features
  • Key points
  • Applications
  • Documentation

Description

The isokinetic sampling system CleanAir Cateco Method 5 is the ideal equipment for particulate sampling to prEN 13284-1/ EPA 40 CFR 60. The Cateco Method 5 also allows sampling to ISO 9096.

Other pollutants can be collected in the bubbling section provided that the correct reagent is used. The CATECO M5 system is identical to the Method 5 system, but the modular sample filtration system is replaced by a more versatile CATECO heated filtration unit. The separation of the probe and filter unit from the glassware makes it easier to use this device for vertical sampling or for hard-to-reach sampling points.

The use of this system must be entrusted to a user trained in a specific methodology. The flow velocity at the sampling point must be known and communicated to CleanAir Europe for the feasibility of the project.

- Certified prEN13284-1, ISO 9096 & EPA 40 CFR 60

 

Available for rent:

The isokinetic dust sampling systemis available for rent from CleanAir Europe

Features

- Isokinetic control console
- CATECO heated filtration unit
- Cateco glassware set
- Bubbler compartment
- Bubbler outlet connection
- Choice of umbilical: 7 / 15 or 30 m
- Method 5 probe: length 60 / 120 or 180 cm
- Complete set of stainless steel nozzles (1/8'', 3/16'', 1/4'', 5/16'', 3/8 '', 1/2'')
- Sample recovery kit
- Glass fibre filters, diameter 8.26 cm
- Stainless steel adapter for port mounting (cable gland)
- Power supply: 230 vac
- Cateco umbilical extension of 3m
- Weight: 60kg

Key points

- Modular system
- Designed for harsh environments
- Customised probe

Applications

- Regulatory control of air emissions
- Continuous emission monitoring (CEM)
- Industrial process control and optimisation
- All types of industries

Documentation

Technical Data
EN Data Sheet
Isokinetic range brochure EN
Isokinetic range brochure EN

Similar products

  • CleanAir Dioxins & Furans (PCDDF)
    Isokinetic Gas System

    Read more View details
  • CleanAir Heavy Metals
    Isokinetic Gas System

    Read more View details
  • CleanAir M5 Dust
    Isokinetic Gas System

    Read more View details
  • CleanAir Corrosive Gases
    Isokinetic Gas System

    Read more View details

360 avenue de la Rasclave
Z.I. Braye de Cau
13821 La Penne-sur-Huveaune
France

+33(0)4 91 87 82 10
cleanair.europe@cleanair.com

OUR EQUIPMENT

  • New measuring instruments
  • Gas Analysers
  • Mercury analyzers & samplers
  • Gas Detectors
  • Particle Counters & Analyzers
  • Dust Samplers
  • Gas Sampling Systems
  • Isokinetic Sampling Systems

    ABOUT

  • Blog
  • Career
  • Contact

OUR SERVICES

  •   Rental
  • Sale
  • Maintenance
  • Calibration
logo CB visa mastercard
Copyright - CleanAir Europe - Enfold Theme by Kriesi
  • LinkedIn
  • Facebook
  • General Conditions of Direct Sales
  • Privacy Policy
HORIBA PG350 E
Analyzer...
CleanAir Dioxins & Furans (PCDDF)...
Scroll up
We use cookies to improve our content and services, but also to provide you with a safer experience. You can accept all cookies or manage your preferences via the "Personalise" menu. Learn more about our use of cookies and data.
CustomizeACCEPT
Manage consent

Setting cookies

Cookies classified as necessary are stored on your browser because they are essential for the basic functionality of our website. We also use third-party cookies that allow us to analyse the performance of our website. You have the option to disable these cookies. Please note, however, that disabling some of these cookies may affect your experience of browsing the site and the online services we can offer you.
Necessary cookies
These cookies are necessary for the proper functioning of our website and its services. These cookies do not store any personally identifiable information.
Performance cookies
These cookies allow us to understand and analyze key analytical performance indicators, which helps to provide a better user experience.
Advertising cookies
These cookies are used to provide visitors with relevant advertising and marketing campaigns. These cookies track visitors to the websites and collect information to provide personalized advertisements.
Save & Apply