Posts

Servomex 1400 item 113

This analyzer measures the CO2 levels in emissions.
The Servomex 1400 uses the principle of infrared absorption.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measurement Range : 0 – 20%, 0 – 25%
– Unit : %
– Detection Limit : 0.1%
– Analog output : 0 – 10V
– Data storage : None (a data recorder can be added).
– Internal pump : No (an external pump can be added).
– Packaged weight : 15 kg
– Number of package : 1
– Recommended for use with : 846, 832, 820, 812, 622, 924

Key Points

– 19’’ rack, 4U
– 2 alarms at 2 thresholds

E sampler item 263

This machine measures dust levels in ambient air.
The E-Sampler uses both a laser and gravimetric analyzer to monitor aerosols and particles in real time.
It is equipped with a data acquisition unit. Life of the battery (included) is 30 hours.
The device is suitable for taking readings both inside and outside buildings. It also indicates ambient temperature, atmospheric pressure and relative humidity.

Specification

– Measuring Range : 0 – 0.5, 0 – 1, 0 – 10 and 0 – 100 mg/m3 (automatic).
– Unit : mg/m3
– Detection Limit : 1 μg/m3
– Sampling Flow-rate : from 1 to 3.5 l/min, temperature and pressure compensated.
– Sampling Period : 1 s
– Accuracy : 3 μg/m3 or 2% of the reading
– Analysis Filter : 47 mm
– Ambient Temperature : -30 to +50 °C
– Atmospheric Pressure : 600 to 1040 hPa
– Data storage : 10,000 readings.
– Internal Pump : yes
– Communication interface : yes
– Software : yes
– Packaged weight : 25 kg
– Number of packages : 2

 

Key Points

– Auto zero and self-calibration (concealable filter) programmable from 15 min to 24 hours

921 CE item 181

This device measures SO2 levels in emissions.
The Ametek 921 CE uses the UV method.
It can be used to continuously monitor emissions after a gas treatment system.

Specification

– Measuring Range : programmable from 0 – 5000 ppm
– Units : ppm
– Flow rate : 1 to 2 l/min
– Detection Limit : 1 ppm
– Analog output : 0 – 10V
– Communication : yes
– Recommended for use with : 846, 832, 820, 622, 922.

Heated probes item 845 et 846

Heated portable sampling probe with filter.
Fitted with a ceramic filter and a 60 cm long, 6 mm diameter stainless steel tube.

Specification

– Stainless steel probe
– Sampling temperature: 600 °C max.
– 2μm ceramic filter
– Heats up to 180°C
– Packaged weight 5 kg, 1 package
– Recommended for use with: 831, 834, 822

 

Key Points

– NOT SUITABLE FOR SAFETY CLASS AREAS

Gas 3100 Item 160

This analyzer measures H2.
The GEIT GAS 3100l uses the principle of the thermal conductivity of a gas.
It can also quantify CO2 to compensate for this interfering gas.

Specification

– Measurement Ranges : 0 – 20 – 100% H2, 0 – 5 – 100% CO2
– Units : %
– Detection limit : 0.01% for H2 and CO2
– Internal Pump : yes
– Analog output : yes
– Communication : yes
– Software : Yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 924

Servomex 1400 item 174

This machine is used to measure O2.
The Servomex 1400 uses magnetic susceptibility to continuously measure O2 levels.
The gas sample must be dry, clean and at room temperature.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measuring range : 0 – 25% and 0 – 100%.
– Units : %
– Detection Limit : 0.1%
– Data storage : none (a data recorder can be added).
– Internal pump : no (an external pump can be added).
– Analog output : 0 – 1V
– Packaged weight : 15 kg
– Number of packages : 1
– Recommended for use with : 812, 820, 831, 846, 622, 924

Key Points

– 2 alarm thresholds

Mark III item 341

This staged sampler has a pre-separator and measures the size distribution of particles from 0.54 μm to 13.6 μm.

It can be mounted on our isokinetic sampling systems. Particle mass is determined by weighing after drying.

Item 341C, a set of substrates for an Andersen impactor (consumables) is required.
 

 

Specification

– Nominal sampling flowrate : 21 liters/min
– Set of nozzles : 1/8’’, 3/16’’, 1/4’’, 5/16’’, 3/8’’, 1/2’’.
– Gas Temperature : 425 °C
– Packaged Weight : 6.5 kg
– Number of packages : 1