AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack

Mini Mite item 141

This machine will convert H2S and TRS into SO2.
The Thermo Mini- Mite uses a thermal oxidation chamber to do this.
The temperature is adjustable depending on the gas to be converted:
– H2S: 650 °C
– TRS: 850 °C

Specification

– Utilization Range : 0 – 1100 °C
– Conversion Range : 0 – 50 ppm H2S
– Yield : > 95%
– Units : °C
– Resolution : 1°C
– Packaged weight : 10 kg
– Number of packages : 2
– Recommended for use with : 250, 235.

CP300 item 315

This machine has a Pitot tube with a K thermocouple for continuously recording the differential pressure and temperature of emissions discharges.

An essential item for your emission gas measuring system.

Supplied with a 1 m Pitot probe and a 3 m umbilical. A speed display readout is available as an option.

Specification

– Measurement Ranges :
   programmable from -10,000 to +10,000 Pa
   programmable from -200 °C to 1300 °C
– Units : Pascal, mm H2O, mbar, in Hg, in H2O
– Detection Limit : 0.1 mm H2O
– Analog Output : 0 – 10V
– Software : Yes
– Packaged Weight : 2 kg for the sensor and 5 kg for the Pitot probe
– Number of packages : 2
– Recommended for use with : 622

 

Key Points

– Programmable automatic zero reset

109L item 194

This device can simultaneously and continuously measure total hydrocarbons, methane containing hydrocarbons and non-methane hydrocarbons.
The Jum 109L uses a flame ionization detector (FID).
Total hydrocarbons are measured directly, methane hydrocarbons are measured after eliminating non-methane compounds and non-methane hydrocarbons are calculated from the difference. It connects directly to a heated output line. It is linear up to 20,000 ppm.

 

Specification

–  Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage: none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V for each channel.
– Packaged weight: 22 kg
– Number of packages: 1
– Recommended for use with: 622, 831, 846, 925, 925M, 928H

Key Points

-19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.

Dioxins and furans item 311D

This system is a version of the base model (dust) and has special glassware for analyzing dioxins and furans.

It can be modified for polycyclic aromatic hydrocarbons.

It can be delivered with 2 sets of glassware (item 311VD), to be ordered separately.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5m, 15m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.
 

PM 10/2,5 item 345 et 346

This cyclone separator is mounted at the end of the sampling probe in the chimney.

The sample is taken at a constant flowrate and particles larger than 10 μm (aerodynamic diameter) are eliminated. Particle mass is determined by weighing after drying.

The PM10/2.5 model samples particles smaller than 10 μm, i.e. those between 10 and 2.5 μm and particles smaller than 2.5μm.

Specification

– Set of 11 nozzles : 3.45 to 9.9 mm
– Spec : PM10 / 2.5
– Filter Diameter : 63 mm (not supplied)
– Packaged weight : 5.8 kg
– Number of packages : 1