ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

AP 360 item 236

This machine measures NOx in the open air to determine air quality or to set a zero baseline before building construction work is carried out.

The Horiba AP360 uses the principle of chemiluminescence.
It can be used after a dilution system on a high concentration application (such as emissions).

 

Specification

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
Communication interface : yes
– Packaged weight : 25 kg
– Number of packages : 1
– Recommended for use with : 622, 921P, 927

3-500 item 192/193

This machine will continuously measure total hydrocarbons.
The Jum 3-500 uses a flame ionization detector (FID).
It connects directly to a heated output line. It is linear up to 20,000 ppm.

Specification

– Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage : none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V
– Packaged weight : 25.5 kg
– Number of packages : 1
– Recommended for use with : 622, 831, 846, 925, 925M, 928 or 928H

Key Points

– 19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.

Aircon II item 466

This high volume sampling system provides an extended range of flowrates.

Designed to collect particles in a factory, it is completely programmable so that you can perform sampling without operator intervention for up to 99 hours.

It can be used for constant flowrates from 2 to 30 liters per minute.

The Aircon II is used in occupational health and safety, the chemical industry, petrochemical industry, interior air measurements and the pharmaceutical industry. It is especially used for sampling asbestos at 7 l/min.
 

Specification

– Completely programmable
– Flowrate adjustable from 2 l/min to 30 l/min.
– Temperate Ranges :
   Operating : -20  C to +45 °C
   Storage : -40 °C to +45 °C
– Instantaneous pressure
– Instantaneous “fault” function
– Battery Life : 8 hours
– Packaged weight : 10 kg

 

AP 360 item 241

This machine measures O3 in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses the principle of UV fluorescence.
It can be used after a dilution system on a high concentration application (such as emissions).

Caractéristiques

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 927

109L item 194

This device can simultaneously and continuously measure total hydrocarbons, methane containing hydrocarbons and non-methane hydrocarbons.
The Jum 109L uses a flame ionization detector (FID).
Total hydrocarbons are measured directly, methane hydrocarbons are measured after eliminating non-methane compounds and non-methane hydrocarbons are calculated from the difference. It connects directly to a heated output line. It is linear up to 20,000 ppm.

 

Specification

–  Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage: none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V for each channel.
– Packaged weight: 22 kg
– Number of packages: 1
– Recommended for use with: 622, 831, 846, 925, 925M, 928H

Key Points

-19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.

C.A.Th.I.A item 470

This device is used for special sampling, particularly asbestos.
The C.A.Th.I.A head is an Alveolar Inhalable Thoracic Aerosol Sensor.
The filter is held between 2 rings which are part of the filter cassette covers so that the whole filter assembly can be removed. The operator does not have to handle the filter at all when installing and removing it.
The machine is supplied with a tripod on request.
 

Specification

– Three selectors : alveolar, inhalable and thoracic
– Flowrate 7l/min
– Filter Cassette-Holder for 37 mm diameter filters
– Meets EN 481, ISO 7708 and FD CEN/TR 15230 standards
– Thoracic selector meets standard NFX 43-050
– Recommended for use with : 466, 475