42i item 233

This machine can measure NO, NO2 and NOx.
The Thermo 42i uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 843, 921P, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
– TCPIP Ethernet Connection

42C item 235

This machine can measure NO, NO2 and NOx.
The Thermo 42C uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 840, 921, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
 

AP 360 item 236

This machine measures NOx in the open air to determine air quality or to set a zero baseline before building construction work is carried out.

The Horiba AP360 uses the principle of chemiluminescence.
It can be used after a dilution system on a high concentration application (such as emissions).

 

Specification

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
Communication interface : yes
– Packaged weight : 25 kg
– Number of packages : 1
– Recommended for use with : 622, 921P, 927

42C-HL item 151

The analyzer can measure NO, NOx and NO2 simultaneously.
The Thermo 42C-HL uses the principle of chemiluminescence to measure emissions of NO (by direct measurement) and NOx and NO2 by conversion to NO.
It is used after an NO2 converter gas treatment system with a yield of greater than 97%.

Specification

– Measurement Range : programmable 0 – 10 ppm and 0 – 5000 ppm
– Units : ppm, mg/m3
– Detection Limit : 50 ppb
– Data storage : 5000 measurement points
– Internal pump : none (external pumps supplied).
– Analog Output : 0 – 10V
– Communication interface: yes
– Software : Yes
– Packaged weight: 50 kg
– Number of packages : 2
– Recommended for use with : 622, 820, 831, 846, 921

Key Points

– Menus for setting parameters and for optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Microprocessor controlled
– Excellent sensitivity
– Reduced sensitivity to interference
– Network connection
– 19’’ rack

42i-HL item 152

The analyzer can measure NO, NOx and NO2 simultaneously.
The Thermo 42I-HL uses the principle of chemiluminescence to measure emissions of NO (by direct measurement) and NOx and NO2 by conversion to NO.
It is used after an NO2 converter gas treatment system with a yield of greater than 97%.

Specification

– Measurement Range : programmable 0 – 10 ppm and 0 – 5000 ppm
– Units : ppm, mg/m3
– Detection Limit : 50 ppb
– Data storage : 5000 measurement points
– Internal pump : none (external pumps supplied).
– Analog Output : 0 – 10V
– Communication interface: yes
– Software : Yes
– Packaged weight: 50 kg
– Number of packages : 2
– Recommended for use with : 622, 820, 831, 846, 921

Key Points

– Menus for setting parameters and for optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Microprocessor controlled
– Excellent sensitivity
– Reduced sensitivity to interference
– Network connection
– 19’’ rack