ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack

Ultramat 23 item 120 121 122

This continuous gas analyzer can measure the CO and CO2 in emissions simultaneously.
The Ultramat 23 uses the principle of infrared absorption.
Several versions with different ranges are available.
The machine can be delivered with its calibration certificate on request (depending on the range).

Specification

– Measurement Ranges:
Item 120 :  0 – 0.05% and 0 – 2.5% CO and 0 – 5% and 0 – 25% CO2
Item 121 : 0 to 1000 ppm CO and 0 to 10,000 ppm CO2 (full scale)
Item 122 : 0 – 10% and 0 – 50% CO and 0 – 1% CO2
– Units : %, mg/m3
– Detection limit : 50 ppm CO / 500 ppm CO2
Item 120 : 50 ppm CO / 500 ppm CO2
Item 121 : 1 ppm CO / 1 ppm CO2
Item 122 : 0.05% ppm CO / 500 ppm CO2
– Data storage : none (a data recorder can be added).
– Internal Pump : yes
– Analog Output : 0 – 10 V
– Packaged weight : 15 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 923, 924.

Key Points

– 19’’ rack, 4U

48C item 124

This analyzer measures CO levels in emissions and in ambient air.
The Thermo 48C uses the principle of infra-red correlation. This technique uses an interference filter to eliminate the effect of the other gases present. It is used on gas which is dry, clean and at room temperature.
It is ideal for very low concentrations.

Specification

– Measurement range : programmable from 0 – 1 ppm to 0 – 10,000 ppm.
– Units : ppm, mg/m3
– Detection Limit : 0.04 ppm
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : 0 – 10 V
– Communication interface : yes
– Software : yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820622, 923

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time
– Linearity specific to scales
– Excellent linearity and reduced sensitivity to interference

330L item 136

This gas analyzer can measure CO and O2. CO2 is calculated depending on the type of fuel.
The Testo 330L uses the principle of an electrochemical cell and is mainly used for small and medium sized boilers.

Specification

– Measurement Range :  0 – 4000 ppm CO and 0 – 20% O2.
– Units : ppm, %
– Data Storage : 200 measurement points
– Detection Limit : 1 ppm CO and 0.1% Vol. O2
– Software : yes
– Packaged weight : 3 kg
– Number of packages : 1

Key Points

– Gas sensor remaining life readout
– Automatic monitoring of level in condensate drain with alert if it is too full
– Error messages with description and diagnostics
– Reminder on date of last maintenance check
– Analyzer internal temperature readout

J2KN item 137

This analyzer can continuously measure O2, CO, NO, NO2 and SO2 for several hours on 2 MW boilers, engines, turbines and so forth.
The Ecom J2kn uses the principle of an electrochemical cell. It includes a pressure sensor and up to 6 electrochemical cells.
The remote control box operates up to 50 m away.
It has a heated line and probe for NO2 measurements and an H2 compensated CO cell. CO2 is calculated from the type of fuel.

Specification

– Measurement Ranges : 0 – 21% O2, 0 – 4000 ppm CO H2 compensated, 0 – 5000 ppm NO, 0 – 1000 ppm NO2, 0 – 5000 ppm SO2
– Units : %, ppm, mg/m3
– Data storage : yes
– Detection Limit : 1 ppm CO, 0.05% O2, 1 ppm CO, 1ppm NO2, 1 ppm SO2
– Internal Pump : yes
– Communication interface : yes
– Software : yes
– Packaged weight : 15 kg
– Number of packages : 1
 

Key Points

– Complies with regulations on compulsory inspection of 4 to 400 kW boilers and 400 kW to 20 MW boilers
– Heated internal exhaust circuit to prevent condensation
– Automatically seeks measuring point with trend display
 

Gas Alert Quattro item 420

The four gas detector Gas Alert Quattro can measure H2S, CO and LELs.

It displays gas concentration in real time on an LCD display.
 

Specification

– Measuring Range : 0 – 200 ppm H2S, 0 – 1000 ppm, 0 – 5% v/v LEL
– Units : ppm and %
– Detection Limit : 0.1 ppm H2S, 0.1% LEL, and 1 ppm CO
– Data Storage : yes
– Communication interface : yes
– Software : yes
– Internal Pump : yes
– Packaged weight : 1 kg
– Number of packages : 1

 

Key Points

– Reduced sensitivity to common industrial gases which generate interference such as methanol or ethanol (CO and H2S sensors).
 

Q-Track item 452

This portable device measures carbon monoxide in ambient air with an electrochemical cell and measures carbon dioxide using non-dispersive infra-red detection.

It can also indicate temperature and relative humidity.

It operates on battery and mains power.

Specification

– Measurement Range : 500 ppm CO, 5000 ppm CO2
– Units : ppm, °C, %
– Temperature : from 0°C to +50°C
– Relative Humidity : 0 – 95%
– Detection Limit : 1 ppm CO, 1 ppm CO2
– Data Storage : 15000 measurement points
– Communication interface : yes
– Software : yes
– Packaged weight : 6 kg
– Number of packages: 1

 

Points clés

– Weight for user : 1 kg
– Powered by 4 AA batteries (1 set in the device, 1 set of new batteries supplied)