Return to the previous page

ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

330L item 136

This gas analyzer can measure CO and O2. CO2 is calculated depending on the type of fuel.
The Testo 330L uses the principle of an electrochemical cell and is mainly used for small and medium sized boilers.

Specification

– Measurement Range :  0 – 4000 ppm CO and 0 – 20% O2.
– Units : ppm, %
– Data Storage : 200 measurement points
– Detection Limit : 1 ppm CO and 0.1% Vol. O2
– Software : yes
– Packaged weight : 3 kg
– Number of packages : 1

Key Points

– Gas sensor remaining life readout
– Automatic monitoring of level in condensate drain with alert if it is too full
– Error messages with description and diagnostics
– Reminder on date of last maintenance check
– Analyzer internal temperature readout

J2KN item 137

This analyzer can continuously measure O2, CO, NO, NO2 and SO2 for several hours on 2 MW boilers, engines, turbines and so forth.
The Ecom J2kn uses the principle of an electrochemical cell. It includes a pressure sensor and up to 6 electrochemical cells.
The remote control box operates up to 50 m away.
It has a heated line and probe for NO2 measurements and an H2 compensated CO cell. CO2 is calculated from the type of fuel.

Specification

– Measurement Ranges : 0 – 21% O2, 0 – 4000 ppm CO H2 compensated, 0 – 5000 ppm NO, 0 – 1000 ppm NO2, 0 – 5000 ppm SO2
– Units : %, ppm, mg/m3
– Data storage : yes
– Detection Limit : 1 ppm CO, 0.05% O2, 1 ppm CO, 1ppm NO2, 1 ppm SO2
– Internal Pump : yes
– Communication interface : yes
– Software : yes
– Packaged weight : 15 kg
– Number of packages : 1
 

Key Points

– Complies with regulations on compulsory inspection of 4 to 400 kW boilers and 400 kW to 20 MW boilers
– Heated internal exhaust circuit to prevent condensation
– Automatically seeks measuring point with trend display
 

Gas Alert Quattro item 420

The four gas detector Gas Alert Quattro can measure H2S, CO and LELs.

It displays gas concentration in real time on an LCD display.
 

Specification

– Measuring Range : 0 – 200 ppm H2S, 0 – 1000 ppm, 0 – 5% v/v LEL
– Units : ppm and %
– Detection Limit : 0.1 ppm H2S, 0.1% LEL, and 1 ppm CO
– Data Storage : yes
– Communication interface : yes
– Software : yes
– Internal Pump : yes
– Packaged weight : 1 kg
– Number of packages : 1

 

Key Points

– Reduced sensitivity to common industrial gases which generate interference such as methanol or ethanol (CO and H2S sensors).
 

Servomex 1400 item 174

This machine is used to measure O2.
The Servomex 1400 uses magnetic susceptibility to continuously measure O2 levels.
The gas sample must be dry, clean and at room temperature.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measuring range : 0 – 25% and 0 – 100%.
– Units : %
– Detection Limit : 0.1%
– Data storage : none (a data recorder can be added).
– Internal pump : no (an external pump can be added).
– Analog output : 0 – 1V
– Packaged weight : 15 kg
– Number of packages : 1
– Recommended for use with : 812, 820, 831, 846, 622, 924

Key Points

– 2 alarm thresholds

Gas 3000 item 547

This portable analyzer can measure CH4, CO2, O2 and H2S for biogas applications.

The GAS 3000 uses infra-red detection for CH4 and CO2 and electrochemical cells for O2 and H2S.

It is used to measure gas in the soil, to monitor landfills and waste processing sites and for biogas quality control.

It is supplied with a probe and a hydrophobic filter.

Specification

– Ranges : 0 – 100% CH4, 0 – 50% CO2, 0 – 25% O2, 0 – 5000 ppm H2S
– Units : %, ppm
– Internal Pump : yes
– Data Storage : yes
– Communication interface : yes
– Software : yes
– Recommended for use with : 622

Key Points

– Battery Life : 4 to 6 hours