Return to the previous page

FLIR GFx320 camera item 530

The FLIR GFx320 is an intrinsically safe infrared camera for methane, hydrocarbons and VOC leak detection.

It meets US EPA regulations for Method 21AWP (Alternative Work Practice). It is also calibrated for temperature measurements.

The camera is small and lightweight for ease of use in tight spaces. This optical gas imaging camera has received sensitivity standard validation from the National Physical Laboratory which means it is compliant with the US EPA rule for the oil and gas industry.

 

            

 

Specification

– Detector type : Indium antimonide (InSb) ;

– Spectral Range : 3,2 to 3,4 μm ;

– IR resolution : 320 x 240 pixels ;

– Hazardous Location Compliance : ATEX/IECEx, Ex ic nC op is IIC T4 Gc II 3 G ;

– GPS : Location data stored with every image ;

– Temperature range : -20 °C to 350 °C (-4 °F to 662 °F) ;

– Display Built-in Widescreen:  4.3″ LCD, 800 x 480 pixels ;

– Focus : Manual ;

– Battery type : Rechargeable Li-ion battery ;

–  Zoom : 1 – 8× continuous digital.

 

 

 

43C item 250

Cet appareil permet de mesurer le SO2.
Le Thermo 43C utilise le principe de la photométrie dans l’ultraviolet. Il possède un dispositif de compensation de température et de pression.
Il peut mesurer le H2S ou TRS après un convertisseur à oxydation thermique.

Caractéristiques

– Gamme de mesure : programmable de 0-1-100ppm
– Seuil de détection : 1 ppb
– Unités : ppb, ppm ou mg/m3 programmable
– Stockage des mesures : 5000 points de mesure
– Pompe interne : oui
– Sortie analogique : 0-10V
– Interface de communication PC : oui
– Logiciel : oui
– Poids emballé : 28 kg
– Nombre de colis : 1
– Conseillé avec articles : 141, 622, 922, 927

Points clés

– Menus de paramétrage et de diagnostics optiques et électroniques
– Commutation automatique d’échelles
– Temps de réponse rapide
– Linéarité sur toutes les échelles
– Susceptibilité réduite aux interférents
– Utiliser du tube PTFE pour limiter les pertes par absorption

330L item 136

This gas analyzer can measure CO and O2. CO2 is calculated depending on the type of fuel.
The Testo 330L uses the principle of an electrochemical cell and is mainly used for small and medium sized boilers.

Specification

– Measurement Range :  0 – 4000 ppm CO and 0 – 20% O2.
– Units : ppm, %
– Data Storage : 200 measurement points
– Detection Limit : 1 ppm CO and 0.1% Vol. O2
– Software : yes
– Packaged weight : 3 kg
– Number of packages : 1

Key Points

– Gas sensor remaining life readout
– Automatic monitoring of level in condensate drain with alert if it is too full
– Error messages with description and diagnostics
– Reminder on date of last maintenance check
– Analyzer internal temperature readout

Jerome J405 item 560

This portable machine will measure mercury vapor in ambient air.

The Jerome J405 uses gold film detection.

It can be used to monitor mercury spillages at hazardous waste sites, dumps, water conduits and so on.
There is very little interference compared to a UV detector.
 

Specification

• Measurement Range : 0.5 – 999 μg/m3
• Unit : μg/m3
• Ambient Air: 0 °C- 45 °C on non-condensable and non-explosive gas.
• Flowrate : 750 cc/min
• Detection Limit : 0.5 μg/m3
• Data Storage: 20000 measurement points
• Internal Pump : yes
• Communication interface : yes
• Software : yes

 

Key Points

• Weight for user : 2.5 kg
• Charger power supply (can operate on a 12V battery, not supplied)
• Automatic zero calibration

Dry Cal-DC Lite item 475

This machine measures the displacement time of a graphite piston in a glass cylinder to calculate volumetric flow in liters per minute. Flow is measured step by step, continuously or continuously with the average. It is used to adjust individual pumps. Specification – Scale from 100 ml/min to 7l/min. – Packaged weight: 2 kg – […]

AP 360 item 236

This machine measures NOx in the open air to determine air quality or to set a zero baseline before building construction work is carried out.

The Horiba AP360 uses the principle of chemiluminescence.
It can be used after a dilution system on a high concentration application (such as emissions).

 

Specification

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
Communication interface : yes
– Packaged weight : 25 kg
– Number of packages : 1
– Recommended for use with : 622, 921P, 927

J2KN item 137

This analyzer can continuously measure O2, CO, NO, NO2 and SO2 for several hours on 2 MW boilers, engines, turbines and so forth.
The Ecom J2kn uses the principle of an electrochemical cell. It includes a pressure sensor and up to 6 electrochemical cells.
The remote control box operates up to 50 m away.
It has a heated line and probe for NO2 measurements and an H2 compensated CO cell. CO2 is calculated from the type of fuel.

Specification

– Measurement Ranges : 0 – 21% O2, 0 – 4000 ppm CO H2 compensated, 0 – 5000 ppm NO, 0 – 1000 ppm NO2, 0 – 5000 ppm SO2
– Units : %, ppm, mg/m3
– Data storage : yes
– Detection Limit : 1 ppm CO, 0.05% O2, 1 ppm CO, 1ppm NO2, 1 ppm SO2
– Internal Pump : yes
– Communication interface : yes
– Software : yes
– Packaged weight : 15 kg
– Number of packages : 1
 

Key Points

– Complies with regulations on compulsory inspection of 4 to 400 kW boilers and 400 kW to 20 MW boilers
– Heated internal exhaust circuit to prevent condensation
– Automatically seeks measuring point with trend display
 

4100 & 6100A item 620 et 622

These 12 channel recorders have analog inputs for voltage, current and a thermocouple output.

User configurations and measurement data can both be saved.

Results are processed with dedicated software and can be converted to Excel if necessary.

The 6100A model has a USB port.

Specification

– Voltage inputs : 20 mV, 60 mV, 200 mV, 2 V, 6 V and 20 V
– Current inputs : available with a shunt resistor
– Thermocouple inputs : R, S, B, K, E, J, T, N, W, L and U
– Data Storage : 26 hours with 1 point/min on each channel
– Software : yes
– Model 6100 A : USB port
– Packaged weight : 5 kg
– Number of packages : 1

 

Key Points

– Recorder, bar graph or display mode
– History stored in memory

AP 360 item 241

This machine measures O3 in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses the principle of UV fluorescence.
It can be used after a dilution system on a high concentration application (such as emissions).

Caractéristiques

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 927

48C item 124

This analyzer measures CO levels in emissions and in ambient air.
The Thermo 48C uses the principle of infra-red correlation. This technique uses an interference filter to eliminate the effect of the other gases present. It is used on gas which is dry, clean and at room temperature.
It is ideal for very low concentrations.

Specification

– Measurement range : programmable from 0 – 1 ppm to 0 – 10,000 ppm.
– Units : ppm, mg/m3
– Detection Limit : 0.04 ppm
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : 0 – 10 V
– Communication interface : yes
– Software : yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820622, 923

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time
– Linearity specific to scales
– Excellent linearity and reduced sensitivity to interference