Return to the previous page

Heated probes item 845 et 846

Heated portable sampling probe with filter.
Fitted with a ceramic filter and a 60 cm long, 6 mm diameter stainless steel tube.

Specification

– Stainless steel probe
– Sampling temperature: 600 °C max.
– 2μm ceramic filter
– Heats up to 180°C
– Packaged weight 5 kg, 1 package
– Recommended for use with: 831, 834, 822

 

Key Points

– NOT SUITABLE FOR SAFETY CLASS AREAS

Gas Cylinders Item 916 to 929S

Gas cylinders are delivered with a stainless steel or brass AFNOR type C or E pressure reducing valve connector.
Consumption is calculated from the difference in incoming and outgoing pressure, corrected for temperature.
CleanAir can provide a wide range of working standard gases (contact us for more details).
These gases are dispatched with a hazardous material declaration.

Pure gases and standard work gases are certified.

Article      Compound
916          NH3/N2
917          N2O/N2
920          O2/CO2/CO/SO2
921          NO/N2
921P        NO/N2 in ppb
922          SO2/N2
922P        SO2/N2 in ppb
923          CO/N2
924          CO2/O2/N2
924P        CO2/N2 in ppb
925          C3H8/N2
925A        C3H8/AIR
925M       CH4/N2
925MA     CH4/AIR
926         N2 100% (5.0)
927         Air
928         H2 100% (5.0)
928H       H2/He 40/60%
929         HCl/N2
929I        I-C4H8/N2
929N      NO2/N2
929S      H2S/N2

 

Gas Cylinders

– Packaged Weight: 15 kg (B11), 1 package per cylinder with safety marking

Pressure-reducing valves by themselves

– Ref. 931: double stage stainless steel C connector
– Ref. 932: double stage brass C or E connector (specify when ordering)
– Packaged weight: 3 kg, 1 box

4100 & 6100A item 620 et 622

These 12 channel recorders have analog inputs for voltage, current and a thermocouple output.

User configurations and measurement data can both be saved.

Results are processed with dedicated software and can be converted to Excel if necessary.

The 6100A model has a USB port.

Specification

– Voltage inputs : 20 mV, 60 mV, 200 mV, 2 V, 6 V and 20 V
– Current inputs : available with a shunt resistor
– Thermocouple inputs : R, S, B, K, E, J, T, N, W, L and U
– Data Storage : 26 hours with 1 point/min on each channel
– Software : yes
– Model 6100 A : USB port
– Packaged weight : 5 kg
– Number of packages : 1

 

Key Points

– Recorder, bar graph or display mode
– History stored in memory

Mak 10.2 item 820

This machine is a gas cooler driven by a R134 fluid compressor.

The portable MAK 10.2 is accurate, safe and stable.

Its unique gas cooling and separation technology enables low and constant dewpoints of 3 °C to be achieved.

It comes in both portable and rack mounted versions.

Specification

– Two gas inlets
– Two pre-separators for dewpoint > 65 °C
– Two heat exchangers
– Two condensate pumps
– Two Teflon filters
– Max flow: 4.5 l/min for relative humidity at 10 %
 

Heated lines item 831 to 835

These heated lines keep the sample above its dewpoint to prevent condensation and prevent soluble compounds from becoming trapped. They can be controlled up to 180 °C.

Specification

– Réf. 834 : 3 m, Packaged weight 3 kg, 1package
– Réf. 833 : 7,5 m, Packaged weight 7 kg, 1package
– Réf. 832 : 15 m, Packaged weight 13 kg, 1package
– Réf. 835 : 20 m, Packaged weight 18 kg, 1package
– Réf. 831 : 30 m, Packaged weight 25 kg, 1package

 

Express Dilution System Item 842

Sonic nozzle dilution probe.
Ideal for reducing concentrations or drying a condensable gas by cooling.
 

Specification

– Dilution ratios 1/16 to 1/300
– Requires on site air instrument zero at 5 bar
– Requires high concentration calibration gas to set the dilution ratio
– Consumption : 6 l/min of dilutant air
– Consumption : 20 to 500 cc of calibration gas
– Packaged weight : 30 kg, 1 crate

 

Key Points

– An instrument air system is recommended.