ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

Skypost item 266

The machine measures dust levels in ambient air.
The sampler can be fitted with a PM10 and PM2.5 cyclone separator.
Dust is removed onto a filter. Measuring sequences are programmable.
The electronic flow controller enables measurements to be performed continuously without operator intervention. Filters can also be easily replaced without interrupting sampling.

Specification

– Internal Pump : yes
– Air Flow : 10 – 50 l/min
– Measuring Sequence :programmable
– Multiple sequences
– Filter Diameter : 47 mm
– Capacity for 16 filters
– Communication interface  : yes
– Power Supply : 230V
– Packaged weight : 50 kg
– Number of packages : 2

 

Key Points

– Automatic flow control
– Adjustable support legs

AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack

42i item 233

This machine can measure NO, NO2 and NOx.
The Thermo 42i uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 843, 921P, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
– TCPIP Ethernet Connection

42C item 235

This machine can measure NO, NO2 and NOx.
The Thermo 42C uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 840, 921, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
 

AP 360 item 236

This machine measures NOx in the open air to determine air quality or to set a zero baseline before building construction work is carried out.

The Horiba AP360 uses the principle of chemiluminescence.
It can be used after a dilution system on a high concentration application (such as emissions).

 

Specification

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
Communication interface : yes
– Packaged weight : 25 kg
– Number of packages : 1
– Recommended for use with : 622, 921P, 927

AP 360 item 241

This machine measures O3 in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses the principle of UV fluorescence.
It can be used after a dilution system on a high concentration application (such as emissions).

Caractéristiques

– Measurement Range : 0-1000 ppb
– Unit : ppb
– Detection Limit : 0,5 ppb
– Data storage : yes
– Internal Pump: yes
– Analog Output : yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 927

49i item 243

This machine is used to measure ozone in ambient air.
The Thermo 49i uses the principle of ultraviolet photometric analysis.
It is temperature and pressure compensated.
 

Specification

– Measurement Range : 0 to 100 ppb and 0 to 200 ppm
– Units : ppm, ppb, μg/m3, mg/m3
– Detection Limit : 1 ppb
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : 0 -10 V
– Communication interface : yes
– Software : yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 927.
 

Key Points

– Internal ozone generator can be used for self-calibration
– Fast response time
– Optical and electronic diagnostics tools