Return to the previous page

ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

Servomex 1400 item 113

This analyzer measures the CO2 levels in emissions.
The Servomex 1400 uses the principle of infrared absorption.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measurement Range : 0 – 20%, 0 – 25%
– Unit : %
– Detection Limit : 0.1%
– Analog output : 0 – 10V
– Data storage : None (a data recorder can be added).
– Internal pump : No (an external pump can be added).
– Packaged weight : 15 kg
– Number of package : 1
– Recommended for use with : 846, 832, 820, 812, 622, 924

Key Points

– 19’’ rack, 4U
– 2 alarms at 2 thresholds

AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack

Gas 3100 Item 160

This analyzer measures H2.
The GEIT GAS 3100l uses the principle of the thermal conductivity of a gas.
It can also quantify CO2 to compensate for this interfering gas.

Specification

– Measurement Ranges : 0 – 20 – 100% H2, 0 – 5 – 100% CO2
– Units : %
– Detection limit : 0.01% for H2 and CO2
– Internal Pump : yes
– Analog output : yes
– Communication : yes
– Software : Yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 924

330L item 136

This gas analyzer can measure CO and O2. CO2 is calculated depending on the type of fuel.
The Testo 330L uses the principle of an electrochemical cell and is mainly used for small and medium sized boilers.

Specification

– Measurement Range :  0 – 4000 ppm CO and 0 – 20% O2.
– Units : ppm, %
– Data Storage : 200 measurement points
– Detection Limit : 1 ppm CO and 0.1% Vol. O2
– Software : yes
– Packaged weight : 3 kg
– Number of packages : 1

Key Points

– Gas sensor remaining life readout
– Automatic monitoring of level in condensate drain with alert if it is too full
– Error messages with description and diagnostics
– Reminder on date of last maintenance check
– Analyzer internal temperature readout

Servomex 1400 item 174

This machine is used to measure O2.
The Servomex 1400 uses magnetic susceptibility to continuously measure O2 levels.
The gas sample must be dry, clean and at room temperature.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measuring range : 0 – 25% and 0 – 100%.
– Units : %
– Detection Limit : 0.1%
– Data storage : none (a data recorder can be added).
– Internal pump : no (an external pump can be added).
– Analog output : 0 – 1V
– Packaged weight : 15 kg
– Number of packages : 1
– Recommended for use with : 812, 820, 831, 846, 622, 924

Key Points

– 2 alarm thresholds