Return to the previous page

921 CE item 181

This device measures SO2 levels in emissions.
The Ametek 921 CE uses the UV method.
It can be used to continuously monitor emissions after a gas treatment system.

Specification

– Measuring Range : programmable from 0 – 5000 ppm
– Units : ppm
– Flow rate : 1 to 2 l/min
– Detection Limit : 1 ppm
– Analog output : 0 – 10V
– Communication : yes
– Recommended for use with : 846, 832, 820, 622, 922.

Aircon II item 466

This high volume sampling system provides an extended range of flowrates.

Designed to collect particles in a factory, it is completely programmable so that you can perform sampling without operator intervention for up to 99 hours.

It can be used for constant flowrates from 2 to 30 liters per minute.

The Aircon II is used in occupational health and safety, the chemical industry, petrochemical industry, interior air measurements and the pharmaceutical industry. It is especially used for sampling asbestos at 7 l/min.
 

Specification

– Completely programmable
– Flowrate adjustable from 2 l/min to 30 l/min.
– Temperate Ranges :
   Operating : -20  C to +45 °C
   Storage : -40 °C to +45 °C
– Instantaneous pressure
– Instantaneous “fault” function
– Battery Life : 8 hours
– Packaged weight : 10 kg

 

Gilair 5 item 462

This personal sampling pump is used to sample various pollutants, dust, VOCs and hydrocarbons. It is used in ambient air.

The GilAir-5 sampling pump can be used for constant flows from 0.5 to 5 l/min. A low flow rate module can be added for lower flows, for either constant flow or constant pressure.

The Gilair 5 is used in occupational health and safety, the chemical industry, petrochemical industry, interior air measurements and the pharmaceutical industry.

Specification

– Intrinsic safety
– Adjustable flowrate from 850 cc/min to 5000 cc/min and 20- 500 cc with low flow module.
– Battery Life: 8 hours approx.
– Packaged weight for 6 pumps: 7.5 kg, 1 case.
– Weight of a pump: 0.7 kg with charger
– Recommended for use with: 475

 

 

Servomex 1400 item 174

This machine is used to measure O2.
The Servomex 1400 uses magnetic susceptibility to continuously measure O2 levels.
The gas sample must be dry, clean and at room temperature.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measuring range : 0 – 25% and 0 – 100%.
– Units : %
– Detection Limit : 0.1%
– Data storage : none (a data recorder can be added).
– Internal pump : no (an external pump can be added).
– Analog output : 0 – 1V
– Packaged weight : 15 kg
– Number of packages : 1
– Recommended for use with : 812, 820, 831, 846, 622, 924

Key Points

– 2 alarm thresholds

Heavy Metal item 311M

It can sample heavy metals.

It is a variant of the base model (dust) and consists of nozzles and a Pyrex or quartz duct with a compartment containing 7 impingers.
 

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5m, 15m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.

Gas 3100 Item 160

This analyzer measures H2.
The GEIT GAS 3100l uses the principle of the thermal conductivity of a gas.
It can also quantify CO2 to compensate for this interfering gas.

Specification

– Measurement Ranges : 0 – 20 – 100% H2, 0 – 5 – 100% CO2
– Units : %
– Detection limit : 0.01% for H2 and CO2
– Internal Pump : yes
– Analog output : yes
– Communication : yes
– Software : Yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 924

Mark III item 341

This staged sampler has a pre-separator and measures the size distribution of particles from 0.54 μm to 13.6 μm.

It can be mounted on our isokinetic sampling systems. Particle mass is determined by weighing after drying.

Item 341C, a set of substrates for an Andersen impactor (consumables) is required.
 

 

Specification

– Nominal sampling flowrate : 21 liters/min
– Set of nozzles : 1/8’’, 3/16’’, 1/4’’, 5/16’’, 3/8’’, 1/2’’.
– Gas Temperature : 425 °C
– Packaged Weight : 6.5 kg
– Number of packages : 1

C.A.Th.I.A item 470

This device is used for special sampling, particularly asbestos.
The C.A.Th.I.A head is an Alveolar Inhalable Thoracic Aerosol Sensor.
The filter is held between 2 rings which are part of the filter cassette covers so that the whole filter assembly can be removed. The operator does not have to handle the filter at all when installing and removing it.
The machine is supplied with a tripod on request.
 

Specification

– Three selectors : alveolar, inhalable and thoracic
– Flowrate 7l/min
– Filter Cassette-Holder for 37 mm diameter filters
– Meets EN 481, ISO 7708 and FD CEN/TR 15230 standards
– Thoracic selector meets standard NFX 43-050
– Recommended for use with : 466, 475

 

VA 3000 item 154

This analyzer measures the N2O levels in emissions.
It uses the principle of infra-red correlation (NDIR) to measure nitrous oxide (N2O) in emissions and in specific processes. Fitted with a CO2 filter to eliminate interference caused by this gas.
It is used after an NO2 converter gas treatment system with a yield of greater than 97%.

Specification

– Measuring range : programmable from 0 – 500 ppm to 0 – 5000 ppm
– Units : ppm, mg/m3
– Detection Limit : 1 ppm
– Internal Pump : yes
– Data storage : none (a data recorder can be added).
– Analog output : yes (0 – 1V or 4 – 20 mA)
– Communication interface : yes
– Packaged weight : 18 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 917.

Key Points

– Reduced heat-up time
– No CO2 interference (optical CO2 filter), reduced CO interference
– Not sensitive to vibration
– Menus for setting parameters and for optical and electronic diagnostics
– Automatic range switchover