42i item 233

This machine can measure NO, NO2 and NOx.
The Thermo 42i uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 843, 921P, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
– TCPIP Ethernet Connection

Dusts item 311 et 311A

This isokinetic manual sampling system will continuously sample gas or vapor in a chimney while maintaining the same speed characteristics as at the sampling point. Particles are removed onto a filter. Hot gases are conditioned in a series of cold bubblers.

Condensate is recovered and a volume flowmeter (DGM) measures the dry gas flowrate.

This system can either be supplied with a heating cabinet or with a Cateco oven box which reduces its overall size.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5 m, 15 m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– Item 311A (Cateco oven box) is particularly suited for difficult sampling operations with its small probe and small oven compartment.
– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.

Gas Cylinders Item 916 to 929S

Gas cylinders are delivered with a stainless steel or brass AFNOR type C or E pressure reducing valve connector.
Consumption is calculated from the difference in incoming and outgoing pressure, corrected for temperature.
CleanAir can provide a wide range of working standard gases (contact us for more details).
These gases are dispatched with a hazardous material declaration.

Pure gases and standard work gases are certified.

Article      Compound
916          NH3/N2
917          N2O/N2
920          O2/CO2/CO/SO2
921          NO/N2
921P        NO/N2 in ppb
922          SO2/N2
922P        SO2/N2 in ppb
923          CO/N2
924          CO2/O2/N2
924P        CO2/N2 in ppb
925          C3H8/N2
925A        C3H8/AIR
925M       CH4/N2
925MA     CH4/AIR
926         N2 100% (5.0)
927         Air
928         H2 100% (5.0)
928H       H2/He 40/60%
929         HCl/N2
929I        I-C4H8/N2
929N      NO2/N2
929S      H2S/N2

 

Gas Cylinders

– Packaged Weight: 15 kg (B11), 1 package per cylinder with safety marking

Pressure-reducing valves by themselves

– Ref. 931: double stage stainless steel C connector
– Ref. 932: double stage brass C or E connector (specify when ordering)
– Packaged weight: 3 kg, 1 box

AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack

Mini Mite item 141

This machine will convert H2S and TRS into SO2.
The Thermo Mini- Mite uses a thermal oxidation chamber to do this.
The temperature is adjustable depending on the gas to be converted:
– H2S: 650 °C
– TRS: 850 °C

Specification

– Utilization Range : 0 – 1100 °C
– Conversion Range : 0 – 50 ppm H2S
– Yield : > 95%
– Units : °C
– Resolution : 1°C
– Packaged weight : 10 kg
– Number of packages : 2
– Recommended for use with : 250, 235.

CP300 item 315

This machine has a Pitot tube with a K thermocouple for continuously recording the differential pressure and temperature of emissions discharges.

An essential item for your emission gas measuring system.

Supplied with a 1 m Pitot probe and a 3 m umbilical. A speed display readout is available as an option.

Specification

– Measurement Ranges :
   programmable from -10,000 to +10,000 Pa
   programmable from -200 °C to 1300 °C
– Units : Pascal, mm H2O, mbar, in Hg, in H2O
– Detection Limit : 0.1 mm H2O
– Analog Output : 0 – 10V
– Software : Yes
– Packaged Weight : 2 kg for the sensor and 5 kg for the Pitot probe
– Number of packages : 2
– Recommended for use with : 622

 

Key Points

– Programmable automatic zero reset

109L item 194

This device can simultaneously and continuously measure total hydrocarbons, methane containing hydrocarbons and non-methane hydrocarbons.
The Jum 109L uses a flame ionization detector (FID).
Total hydrocarbons are measured directly, methane hydrocarbons are measured after eliminating non-methane compounds and non-methane hydrocarbons are calculated from the difference. It connects directly to a heated output line. It is linear up to 20,000 ppm.

 

Specification

–  Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage: none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V for each channel.
– Packaged weight: 22 kg
– Number of packages: 1
– Recommended for use with: 622, 831, 846, 925, 925M, 928H

Key Points

-19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.

Dioxins and furans item 311D

This system is a version of the base model (dust) and has special glassware for analyzing dioxins and furans.

It can be modified for polycyclic aromatic hydrocarbons.

It can be delivered with 2 sets of glassware (item 311VD), to be ordered separately.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5m, 15m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.
 

PM 10/2,5 item 345 et 346

This cyclone separator is mounted at the end of the sampling probe in the chimney.

The sample is taken at a constant flowrate and particles larger than 10 μm (aerodynamic diameter) are eliminated. Particle mass is determined by weighing after drying.

The PM10/2.5 model samples particles smaller than 10 μm, i.e. those between 10 and 2.5 μm and particles smaller than 2.5μm.

Specification

– Set of 11 nozzles : 3.45 to 9.9 mm
– Spec : PM10 / 2.5
– Filter Diameter : 63 mm (not supplied)
– Packaged weight : 5.8 kg
– Number of packages : 1

 

3-500 item 192/193

This machine will continuously measure total hydrocarbons.
The Jum 3-500 uses a flame ionization detector (FID).
It connects directly to a heated output line. It is linear up to 20,000 ppm.

Specification

– Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage : none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V
– Packaged weight : 25.5 kg
– Number of packages : 1
– Recommended for use with : 622, 831, 846, 925, 925M, 928 or 928H

Key Points

– 19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.