ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

FLIR GFx320 camera item 530

The FLIR GFx320 is an intrinsically safe infrared camera for methane, hydrocarbons and VOC leak detection.

It meets US EPA regulations for Method 21AWP (Alternative Work Practice). It is also calibrated for temperature measurements.

The camera is small and lightweight for ease of use in tight spaces. This optical gas imaging camera has received sensitivity standard validation from the National Physical Laboratory which means it is compliant with the US EPA rule for the oil and gas industry.

 

            

 

Specification

– Detector type : Indium antimonide (InSb) ;

– Spectral Range : 3,2 to 3,4 μm ;

– IR resolution : 320 x 240 pixels ;

– Hazardous Location Compliance : ATEX/IECEx, Ex ic nC op is IIC T4 Gc II 3 G ;

– GPS : Location data stored with every image ;

– Temperature range : -20 °C to 350 °C (-4 °F to 662 °F) ;

– Display Built-in Widescreen:  4.3″ LCD, 800 x 480 pixels ;

– Focus : Manual ;

– Battery type : Rechargeable Li-ion battery ;

–  Zoom : 1 – 8× continuous digital.

 

 

 

Servomex 1400 item 113

This analyzer measures the CO2 levels in emissions.
The Servomex 1400 uses the principle of infrared absorption.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measurement Range : 0 – 20%, 0 – 25%
– Unit : %
– Detection Limit : 0.1%
– Analog output : 0 – 10V
– Data storage : None (a data recorder can be added).
– Internal pump : No (an external pump can be added).
– Packaged weight : 15 kg
– Number of package : 1
– Recommended for use with : 846, 832, 820, 812, 622, 924

Key Points

– 19’’ rack, 4U
– 2 alarms at 2 thresholds

Gas 3100 Item 160

This analyzer measures H2.
The GEIT GAS 3100l uses the principle of the thermal conductivity of a gas.
It can also quantify CO2 to compensate for this interfering gas.

Specification

– Measurement Ranges : 0 – 20 – 100% H2, 0 – 5 – 100% CO2
– Units : %
– Detection limit : 0.01% for H2 and CO2
– Internal Pump : yes
– Analog output : yes
– Communication : yes
– Software : Yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 924

Mark III item 341

This staged sampler has a pre-separator and measures the size distribution of particles from 0.54 μm to 13.6 μm.

It can be mounted on our isokinetic sampling systems. Particle mass is determined by weighing after drying.

Item 341C, a set of substrates for an Andersen impactor (consumables) is required.
 

 

Specification

– Nominal sampling flowrate : 21 liters/min
– Set of nozzles : 1/8’’, 3/16’’, 1/4’’, 5/16’’, 3/8’’, 1/2’’.
– Gas Temperature : 425 °C
– Packaged Weight : 6.5 kg
– Number of packages : 1

C.A.Th.I.A item 470

This device is used for special sampling, particularly asbestos.
The C.A.Th.I.A head is an Alveolar Inhalable Thoracic Aerosol Sensor.
The filter is held between 2 rings which are part of the filter cassette covers so that the whole filter assembly can be removed. The operator does not have to handle the filter at all when installing and removing it.
The machine is supplied with a tripod on request.
 

Specification

– Three selectors : alveolar, inhalable and thoracic
– Flowrate 7l/min
– Filter Cassette-Holder for 37 mm diameter filters
– Meets EN 481, ISO 7708 and FD CEN/TR 15230 standards
– Thoracic selector meets standard NFX 43-050
– Recommended for use with : 466, 475

 

VA 3000 item 154

This analyzer measures the N2O levels in emissions.
It uses the principle of infra-red correlation (NDIR) to measure nitrous oxide (N2O) in emissions and in specific processes. Fitted with a CO2 filter to eliminate interference caused by this gas.
It is used after an NO2 converter gas treatment system with a yield of greater than 97%.

Specification

– Measuring range : programmable from 0 – 500 ppm to 0 – 5000 ppm
– Units : ppm, mg/m3
– Detection Limit : 1 ppm
– Internal Pump : yes
– Data storage : none (a data recorder can be added).
– Analog output : yes (0 – 1V or 4 – 20 mA)
– Communication interface : yes
– Packaged weight : 18 kg
– Number of packages : 1
– Recommended for use with : 846, 832, 820, 622, 917.

Key Points

– Reduced heat-up time
– No CO2 interference (optical CO2 filter), reduced CO interference
– Not sensitive to vibration
– Menus for setting parameters and for optical and electronic diagnostics
– Automatic range switchover