ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

FLIR GFx320 camera item 530

The FLIR GFx320 is an intrinsically safe infrared camera for methane, hydrocarbons and VOC leak detection.

It meets US EPA regulations for Method 21AWP (Alternative Work Practice). It is also calibrated for temperature measurements.

The camera is small and lightweight for ease of use in tight spaces. This optical gas imaging camera has received sensitivity standard validation from the National Physical Laboratory which means it is compliant with the US EPA rule for the oil and gas industry.

 

            

 

Specification

– Detector type : Indium antimonide (InSb) ;

– Spectral Range : 3,2 to 3,4 μm ;

– IR resolution : 320 x 240 pixels ;

– Hazardous Location Compliance : ATEX/IECEx, Ex ic nC op is IIC T4 Gc II 3 G ;

– GPS : Location data stored with every image ;

– Temperature range : -20 °C to 350 °C (-4 °F to 662 °F) ;

– Display Built-in Widescreen:  4.3″ LCD, 800 x 480 pixels ;

– Focus : Manual ;

– Battery type : Rechargeable Li-ion battery ;

–  Zoom : 1 – 8× continuous digital.

 

 

 

Servomex 1400 item 113

This analyzer measures the CO2 levels in emissions.
The Servomex 1400 uses the principle of infrared absorption.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measurement Range : 0 – 20%, 0 – 25%
– Unit : %
– Detection Limit : 0.1%
– Analog output : 0 – 10V
– Data storage : None (a data recorder can be added).
– Internal pump : No (an external pump can be added).
– Packaged weight : 15 kg
– Number of package : 1
– Recommended for use with : 846, 832, 820, 812, 622, 924

Key Points

– 19’’ rack, 4U
– 2 alarms at 2 thresholds

109L item 194

This device can simultaneously and continuously measure total hydrocarbons, methane containing hydrocarbons and non-methane hydrocarbons.
The Jum 109L uses a flame ionization detector (FID).
Total hydrocarbons are measured directly, methane hydrocarbons are measured after eliminating non-methane compounds and non-methane hydrocarbons are calculated from the difference. It connects directly to a heated output line. It is linear up to 20,000 ppm.

 

Specification

–  Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage: none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V for each channel.
– Packaged weight: 22 kg
– Number of packages: 1
– Recommended for use with: 622, 831, 846, 925, 925M, 928H

Key Points

-19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.

Dioxins and furans item 311D

This system is a version of the base model (dust) and has special glassware for analyzing dioxins and furans.

It can be modified for polycyclic aromatic hydrocarbons.

It can be delivered with 2 sets of glassware (item 311VD), to be ordered separately.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5m, 15m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.
 

PM 10/2,5 item 345 et 346

This cyclone separator is mounted at the end of the sampling probe in the chimney.

The sample is taken at a constant flowrate and particles larger than 10 μm (aerodynamic diameter) are eliminated. Particle mass is determined by weighing after drying.

The PM10/2.5 model samples particles smaller than 10 μm, i.e. those between 10 and 2.5 μm and particles smaller than 2.5μm.

Specification

– Set of 11 nozzles : 3.45 to 9.9 mm
– Spec : PM10 / 2.5
– Filter Diameter : 63 mm (not supplied)
– Packaged weight : 5.8 kg
– Number of packages : 1

 

3-500 item 192/193

This machine will continuously measure total hydrocarbons.
The Jum 3-500 uses a flame ionization detector (FID).
It connects directly to a heated output line. It is linear up to 20,000 ppm.

Specification

– Measurement Range : 0 – 10, 10 – 100, 0 – 1000 and 0 – 20,000 ppm (linear) and above that logarithmically.
– Units : ppm
– Detection Limit : 1/1000th of the range.
– Fuel Gas: H2/He, 40/60% vol.
– FID Temperature : 190 °C
– Data storage : none (a data recorder can be added).
– Internal Pump : yes
– Analog output: 0 – 10V
– Packaged weight : 25.5 kg
– Number of packages : 1
– Recommended for use with : 622, 831, 846, 925, 925M, 928 or 928H

Key Points

– 19’’ rack, 3U.
– FID burner can be used in ambient air with an activated charcoal filter.