ETG MCA 100 BIO-P ITEM 546 AMBIENT AIR AND PROCESS

This system is suitable for the measurement of the biogas in a single point, and performs continuous measurement of CH4, CO2,CO, O2 and H2S.

The MCA 100 P is the portable version of the MCA 100 Bio and has been designed for those who need to monitor the composition of the biogas at several points.

The analyzer is mounted inside a hard case impact resistant, equipped with touch screen monitor ( 5.7”), capable of recording up to 1000 data analysis, has an autonomy of 8 hours.

 

CH4, CO and CO2 board NDIR based

 

O2, H2S board electro chemical cell based

 

Specifications

– Ranges :

  • CH4 0…100 vol% (NDIR)
  • CO2 0…50% (NDIR)
  • CO 0…1% (NDIR)
  • O2 0…25 vol% (ECD)
  • H2S 0…5000 ppm (ECD)
  • Calorific Value

– Unit : %, PPM

– Data logging : Yes

– Software : Yes

– Internal pump : Yes

– Analog output : No

– Weigth : 8 kg

– Number of box : 1

– Recommended for use with: 822

Key Points :

– Real-Time analysis

– Remotable by Ethernet

– Trend of the last 30 minutes for each measured compound

– Dust filter on sample line

– Sampling pump

– Data Download .csv format by USB port

 

 

 

FLIR GFx320 camera item 530

The FLIR GFx320 is an intrinsically safe infrared camera for methane, hydrocarbons and VOC leak detection.

It meets US EPA regulations for Method 21AWP (Alternative Work Practice). It is also calibrated for temperature measurements.

The camera is small and lightweight for ease of use in tight spaces. This optical gas imaging camera has received sensitivity standard validation from the National Physical Laboratory which means it is compliant with the US EPA rule for the oil and gas industry.

 

            

 

Specification

– Detector type : Indium antimonide (InSb) ;

– Spectral Range : 3,2 to 3,4 μm ;

– IR resolution : 320 x 240 pixels ;

– Hazardous Location Compliance : ATEX/IECEx, Ex ic nC op is IIC T4 Gc II 3 G ;

– GPS : Location data stored with every image ;

– Temperature range : -20 °C to 350 °C (-4 °F to 662 °F) ;

– Display Built-in Widescreen:  4.3″ LCD, 800 x 480 pixels ;

– Focus : Manual ;

– Battery type : Rechargeable Li-ion battery ;

–  Zoom : 1 – 8× continuous digital.

 

 

 

Servomex 1400 item 113

This analyzer measures the CO2 levels in emissions.
The Servomex 1400 uses the principle of infrared absorption.
It is used after a gas preparation system.
Set-points can be pre-defined and an alarm can be sounded if they are exceeded. A flow-rate alarm is also available.
The 0 – 10 V analog output can be used to record the data on a plotter.

Specification

– Measurement Range : 0 – 20%, 0 – 25%
– Unit : %
– Detection Limit : 0.1%
– Analog output : 0 – 10V
– Data storage : None (a data recorder can be added).
– Internal pump : No (an external pump can be added).
– Packaged weight : 15 kg
– Number of package : 1
– Recommended for use with : 846, 832, 820, 812, 622, 924

Key Points

– 19’’ rack, 4U
– 2 alarms at 2 thresholds

42i item 233

This machine can measure NO, NO2 and NOx.
The Thermo 42i uses the principle of chemiluminescence.
It alternately measures NO (directly) and then NOx (via the converter).
It displays the 3 parameters continuously, for NO, NO2 and NOx.
It can be used after a dilution system on a high concentration application (such as emissions).

Specification

– Measurement Range : programmable from 0 – 0.05 ppm to 0 – 100 ppm.
– Units : ppb or mg/m3 programmable
– Detection Limit : 0.4 ppb
– Data storage : 5000 measurement points
– Internal Pump : yes
– Analog Output : yes
– Communication interface : yes
– Software : Yes
– Packaged weight : 28 kg
– Number of packages : 1
– Recommended for use with : 622, 843, 921P, 927.

Key Points

– Menus for setting parameters and optical and electronic diagnostics
– Automatic range switchover
– Fast response time, linearity on all ranges
– Reduced sensitivity to interference
– TCPIP Ethernet Connection

Dusts item 311 et 311A

This isokinetic manual sampling system will continuously sample gas or vapor in a chimney while maintaining the same speed characteristics as at the sampling point. Particles are removed onto a filter. Hot gases are conditioned in a series of cold bubblers.

Condensate is recovered and a volume flowmeter (DGM) measures the dry gas flowrate.

This system can either be supplied with a heating cabinet or with a Cateco oven box which reduces its overall size.

Specification

– Sampling flow rate : depending on the isokinetic parameters < 40 liters/min
– Length of probe : 0.6 m, 0.9 m, 1.2 m, 1.5 m, 1.8 m, stainless steel (specify length with order).
– Umbilical : 7.5 m, 15 m or 30 m (specify with order).
– Set of Nozzles : 3, 4, 5, 7, 9 and 12 mm (stainless steel).
– Gas Temperature : 200 °C max (optionally 600 °C max).
– Oven Temperature : 120 °C
– Calculation Sheet : in Excel® (supplied)
– Packaged weight : 120 kg
– Number of packages : 5

 

Key Points

– Item 311A (Cateco oven box) is particularly suited for difficult sampling operations with its small probe and small oven compartment.
– This device must only be used by an operator trained in a specific methodology. The flow speed at the sampling point must be known and communicated to CleanAir Europe for assessing the feasibility of the project.

Gas Cylinders Item 916 to 929S

Gas cylinders are delivered with a stainless steel or brass AFNOR type C or E pressure reducing valve connector.
Consumption is calculated from the difference in incoming and outgoing pressure, corrected for temperature.
CleanAir can provide a wide range of working standard gases (contact us for more details).
These gases are dispatched with a hazardous material declaration.

Pure gases and standard work gases are certified.

Article      Compound
916          NH3/N2
917          N2O/N2
920          O2/CO2/CO/SO2
921          NO/N2
921P        NO/N2 in ppb
922          SO2/N2
922P        SO2/N2 in ppb
923          CO/N2
924          CO2/O2/N2
924P        CO2/N2 in ppb
925          C3H8/N2
925A        C3H8/AIR
925M       CH4/N2
925MA     CH4/AIR
926         N2 100% (5.0)
927         Air
928         H2 100% (5.0)
928H       H2/He 40/60%
929         HCl/N2
929I        I-C4H8/N2
929N      NO2/N2
929S      H2S/N2

 

Gas Cylinders

– Packaged Weight: 15 kg (B11), 1 package per cylinder with safety marking

Pressure-reducing valves by themselves

– Ref. 931: double stage stainless steel C connector
– Ref. 932: double stage brass C or E connector (specify when ordering)
– Packaged weight: 3 kg, 1 box

AP 360 item 220

This machine measures CO in the open air to determine air quality or to set a zero baseline before building construction work is carried out.
The Horiba AP360 uses NDIR detection.

Specification

– Measurement Range : 0 – 100 ppm
– Units : ppm
– Detection Limit : 0.02 ppm
– Data storage : Yes
– Internal pump : yes
– Analog output : Yes
– Communication interface : yes
– Packaged weight : 20 kg
– Number of packages : 1
– Recommended for use with : 622, 923, 927.

Key PointsPoints clés

– 19’’ rack